Supermarket Goods Scissor Lift Restored to Service

August 25, 2026

Overcoming a leaking hydraulic cylinder and seized retaining pins.

A leading supermarket relies on a goods scissor lift at one of its busy sites to support the safe and efficient movement of stock through the building.

Goods-handling equipment plays an essential role behind the scenes in busy retail environments. Deliveries must be received, processed and transferred to the appropriate storage or retail areas without creating unnecessary delays for colleagues of affecting stock availability.

When the lift’s main hydraulic cylinder developed a leak, the customer required a specialist repair to restore the equipment to safe and reliable operation.

The Challenge

EquipservUK attended the site to replace the leaking main hydraulic cylinder as part of the agreed scissor lift repair work.

A hydraulic leak affects the performance and reliability of a scissor lift. Loss of hydraulic oil may also contribute to further mechanical and operational problems if the underlying fault is not addressed.

Although the required repair had been identified, removing the original cylinder presented an additional engineering challenge. Both retaining pins securing the cylinder assembly were firmly seized and could not be removed using standard methods.

Restricted access around the assembly and the condition of the pins meant that the cylinder could not simply be disconnected and lifted out. A safe and controlled removal method was needed before the replacement cylinder could be installed.

A Controlled and Practical Solution

Before starting the work, the EquipservUK engineer made the surrounding area safe and raised the scissor lift onto its safety props. This mechanically supported the platform and provided a controlled working environment beneath the equipment.

The front safety curtain was then removed to provide access to the hydraulic cylinder and its retaining points.

Initial attempts to release the first retaining pin using controlled heat were unsuccessful. The engineer therefore carefully cut out the seized pin, allowing the leaking cylinder to be repositioned and providing access to the second retaining point.

The remaining pin was also firmly seized. By adapting the removal method to suit the condition of the equipment, the engineer successfully freed both pins while protecting the lift structure and the components that would remain in service.

Installing the Replacement Cylinder

Once the seized retaining pins had been removed, the leaking hydraulic cylinder was disconnected and taken out of the lift.

The replacement main hydraulic cylinder was manoeuvred into position and connected to the equipment. A new retaining pin and securely welded retaining assembly were then installed to complete the mechanical repair.

Following installation, the hydraulic system was replenished with 15 litres of hydraulic oil. The engineer inspected the completed work and prepared the lift for operational testing.

Testing and Return to Service

The safety props were removed, and the scissor lift was tested over six complete operational cycles.

During testing, the engineer monitored the movement and performance of the lift, along with the replacement cylinder and its connections. No further leaks or operating issues were identified.

The successful test cycles confirmed that the new hydraulic cylinder was functioning correctly and that the system was operating as intended. The goods scissor lift was left fully working and ready to resume its important role in the supermarket’s back-of-house stock handling operation.

Practical Support for Complex Repairs

This project demonstrates how an apparently routine component replacement can become more complex once work begins.

Age, corrosion, wear and demanding operating conditions can cause retaining pins and other mechanical components to seize over time. When this happens, completing the work requires more than the correct replacement parts. Engineers must be able to assess the equipment, adapt their approach and use suitable removal techniques without causing avoidable damage to the surrounding structure.

EquipservUK combines technical lifting-equipment knowledge with practical on-site engineering experience. From isolating and supporting equipment through to component removal, installation and final testing, our engineers manage every stage of the repair process.

If a hydraulic leak, seized component or equipment failure is affecting your operation, contact EquipservUK to discuss how we can help return your machinery to safe and reliable service.

See the full case study at the link below:

Scissor lift case study